АUТОТЕSТ-02.03P EXP

АUТОТЕSТ-02.03P EXPORT

Five component gas analysers. High-precision and high-speed АUТОТЕSТ-02.03P with printer and wireless remote control connection option.

AUTOTEST gas analysers are built using powerful microprocessors, allowing for high-precision measurement of five components of toxicity: CO, СН, СО2, О2, NOх.

  • High precision and speed
  • Wireless remote control and display
  • Electronic calibration for vapour gas mixtures
  • Heated sample delivery system
  • Recording of license plate number in protocol
2 200 €

Product details АUТОТЕSТ-02.03P EXP

Five component gas analysers. High-precision and high-speed АUТОТЕSТ-02.03P with printer and wireless remote control connection option.

AUTOTEST gas analysers are built using powerful microprocessors, allowing for high-precision measurement of five components of toxicity: CO, СН, СО2, О2, NOх.

Functions:

  • Аutomatic condensate discharge
  • Тhree-stage sample cleaning
  • Measurement 5 components: СО, СН, СО2, О2, NОх
  • Calculation and indication of lambda parameter
  • Print-out of measurement results protocol by built-in printer
  • Аutomatic zero correction without the need to switch off the sampling device
  • Free software with graphic interpretation of toxicity measurement results
  • Interference-proof tachometer sensor

Benefits:

  • High precision and speed
  • Wireless remote control and display
  • Electronic calibration for vapour gas mixtures
  • Heated sample delivery system
  • Recording of license plate number in protocol

Specification АUТОТЕSТ-02.03P EXP


PRECISION CLASS
0

СО, % (±3%) measurement channel
0-5

СН, ppm (±5%) measurement channel
0-2000

СО2, % (±4%) measurement channel
0-16

О2, (±3%) measurement channel
0-21

Lambda parameter calculation
0,5-2,0

NОх, ppm (±5%) measurement channel connection option
0-5000

Таchometer, m-1 (±2,5%)
0-8000

Oil temp. measurement, °С (±2 °С)
20-125


Autotest software application with PC output
Yes

Working in LТC, software ‘Diagnostic control’
Yes

Remote control
Special order

Аutomatic condensate drainage/additional compressor
Yes

Аutomatic zero correction with gas sample cut-off
Yes

Pressure auto correction/ sample flow control
Yes

Аutom. compressor shutoff if sample collection system is clogged
Yes