SТМ 3000М.02 EXP

SТМ 3000М.02 EXP

Low-profile compact brake stand with an axle load of up to 3 tons

8 950 €

Product details SТМ 3000М.02 EXP

Compact, low-profile roller break tester for testing AWD passenger cars and of mini-buses with axle load of up to 3 t, track width up from 800 to 220 mm and wheel diameter from 500 to 850 mm. Ramp height 160 mm.
Optimal arrangement version for technical control stations and mobile technical inspection stations. Supplied as a mobile option with a trailer. Thanks to RBT unit weighing 170 kg made of two parts it is easy to move the stand and this makes it possible to set up a travelling technical inspection point with a portable brake test stand which may be transported in the trailer. Recommended dimensions of industrial premises - 5 х18 m.

Specification SТМ 3000М.02 EXP


Initial braking speed, simulated on the stand, at least
2 km/h

Measuring range of the braking force at each wheel, axle checked
From 0 to 10 kN

Limit allowable relative error,not more
±3%

Measuring range of the control force
From 0 to 1000 N

Limit allowable relative error,not more
±5%

The range of measurement of mass (weight) of the axis
From 0 to 3500 kg

Limit allowable relative error,not more
±3%

Power of stand consumption, not more
4 kW

Parameters of the three-phase four-wire power supply with a tolerance of 12 according to GOST 997-84 - Voltage in V
380+10%-15%

Parameters of the three-phase four-wire power supply with a tolerance of 12 according to GOST 997-84 - Frequency, Hz
50±1

Warm-up time not more
15 min

Continuous operation of the stand, not less
8 h


Overall dimensions, not more - Roller set (left, right)
1340х735х230 mm

Overall dimensions, not more - Control cabinet
550х460х120 mm

Overall dimensions, not more - Traffic light
70х200х200 mm

Height of ramp mm
160+10

Weight, not more - Roller setting
170х2 kg

Weight, not more - Control cabinet
20 kg

Weight, not more - Traffic Light
5 kg

Operating temperature range
From -30 to +50 ºC

Average life not less
8 years

Mean time to failure device not less
1000 h

Average recovery time working condition, no more
6,4 h